Wednesday, November 6, 2019
Determination Of Chlorinated Phenols Based On Chromatographic Techniques Biology Essay Essays
Determination Of Chlorinated Phenols Based On Chromatographic Techniques Biology Essay Essays Determination Of Chlorinated Phenols Based On Chromatographic Techniques Biology Essay Essay Determination Of Chlorinated Phenols Based On Chromatographic Techniques Biology Essay Essay Chlorinated phenols are well-known environmental pollutants which are widely distributed in natural Waterss and dirts because of their extended use in many industrial and agricultural procedures such as the industry of plastics, dyes, drugs, antiseptics, germicides, intermediates in chemical production and pesticides. In add-on, Chlorophenols ( CPs ) are besides generated during the chlorine intervention of imbibing H2O [ 29 ] and every bit good as by the debasement of phenoxy weedkillers. Because to their toxicity in aquatic life and hapless biotreatability, US Environmental Protection Agency ( EPA ) have included chlorophenols in their lists of precedence pollutants and considered as of import environmental hazards. The European Community statute law has besides set maximal admissible phenols concentration of 0.5 ng/mL in tap H2O [ 7 ] . In Taiwan, serious pollutions of CPs in dirt and H2O have been reported due to assorted industrial and agricultural activi ties [ 1 ] . On this footing, the finding of this category of compounds in the environment is of great importance. Therefore, an accurate and sensitive method is required for the finding of CPs in environmental samples. Most of the analytical methods for finding of CPs are based on chromatographic techniques such as high public presentation liquid chromatography ( HPLC ) [ 8-10 ] , gas chromatography ( GC ) [ 11-13 ] and capillary cataphoresis [ 14,15 ] . In GC analysis, because of high mutual opposition of CPs compounds, they lend to wide, tailed extremums, and these effects led to high sensing bounds. To avoid this drawback, the CPs have to be derivatized with a suited derivatization reagent before injection into the GC. On the other manus, HPLC is a good option technique, in which isocratic or gradient elution can be used to divide the phenolic compounds and it has been widely used for the separation and finding of CPs [ 30-33 ] , and is frequently coupled with assorted sensors such as UV ( UV ) [ 31,34 ] , fluorescence [ 35 ] , and electrochemical [ 36 ] . However, because of the comparatively low concentrations of most CPs and the built-in complexness in environmental H2O samples, a preconcentr ation measure normally becomes necessary, prior to their analysis. Over the past decennaries, Liquid-liquid extraction ( LLE ) [ 13 ] and solid-phase extraction ( SPE ) [ 14 ] are the most widely used techniques for the preconcentration of CPs in environmental samples. Normally, both the techniques needs an appreciable sum of toxic dissolver for extraction or elution stairss, and the extracted dissolvers are required to vaporize to concentrate the sample and reconstitution for the subsequent HPLC analysis which are time-consuming, boring, and risky to the operators and consequence in menace to the environment. In the last decennary, there is an emerging tendency towards the miniaturisation of chemical analysis systems which consists of several distinguishable advantages such as rapid analysis, simplification and smaller sample volume. Furthermore, an environmentally friendly characteristic of the miniaturized analysis systems is that the ingestion of reagents is reduced. Solid-phase microextraction ( SPME ) technique has been developed as a simple, rapid, and less solvent ingestion procedure [ 9 ] typically applied to CP trying [ 10-12 ] . SPME is largely combined with GC-flame ionisation sensing ( FID ) or GC-mass spectroscopy ( MS ) for analysis ; nevertheless, derivatization is normally still required in this technique. When SPME is coupled to HPLC or CE, a solvent desorption measure is required to retrieve all sorbed analytes and to avoid transfer. Owing to these grounds, most current applications of SPME are limited to non-polar or average polar compounds [ 19 ] . Recently, a fast, simple, cheap and virtually solvent less sample readying method was developed for the preconcentration of the mark pollutants from H2O, this technique is known as single-drop microextraction ( SDME ) [ 20-24 ] . It is a miniaturisation of the traditional liquid-liquid extraction ( LLE ) technique, which is based on the extraction of analytes in a mirolitre bead of a H2O non-miscible dissolver is suspended in the acerate leaf of a microsyringe that can be straight immersed in the aqueous sample ( DI-SDME ) or in its headspace ( HS-SDME ) [ 33 ] . When the extraction finished, the microdrop is retracted back into the microsyringe and injected to the instrument such as gas chromatograph ( GC ) and high public presentation liquid chromatography ( HPLC ) for farther analysis. The research group of Lee farther developed this technique by presenting the constructs of inactive and dynamic microextraction combined with GC [ 11-13 ] . This technique is inexpensive and there i s minimum exposure to toxic organic dissolvers. SDME has been applied for the finding of organochlorine insect powders and organophosphorous insect powders [ 25-34 ] , etc. , . Although organic dissolvers have been normally used as extractants in SDME, a high instability of the bead and hapless preciseness degrees have been reported as a consequence of the organic extractant vaporization and low viscousness. Ionic liquids ( ILs ) emerged as an option to these conventional dissolvers as they present alone and valuable belongingss including low vapor force per unit area, high viscousness or good thermic stableness, moderate dissolvability of organic compounds every bit good as adjustable miscibility and mutual opposition [ 2-5 ] . These belongingss make these dissolvers absolutely suited for SDME since larger and more consistent pull outing volumes can be used [ 34 ] . The ionic liquid-based individual bead microextraction has been antecedently used for the finding of pollutants with HPLC [ 35-37 ] or GC finding [ 38,39 ] . The chief advantages of ILs when used for SDME are that they allow the application of longer trying times every bit good as the usage of larger bead volumes, therefore taking to the development of high-performance liquid chromatography ( HPLC ) protocols with increased sensitiveness. The pertinence of microwave energy for the extraction of pollutants from environmental samples has been investigated for the last 10 old ages and new analytical methodological analysiss have been developed ( ) . Microwaves straight couple with the analytes present in the sample matrix taking to an instantaneous localised superheating ( In order to shorten the sampling clip of HS-SPME, microwave warming was utilized for the rapid acceleration of vaporisation of analytes from the sample matrix to headspace and rapid analysis was achieved for polychlorinated biphenyls ( ) , organochlorinated pesticides ( ) , pyrethroids ( ) , chlorobenzenes ( ) and polycyclic aromatic hydrocarbons ( ) in H2O samples. Subsequently on, microwave warming was besides tried coupled with HS-LPME or HS-SDME for the possible betterments in the analysis of semi-volatile pollutants in Waterss [ ] , However, when microwave warming was applied to modify HS-LPME, it resulted in the important vaporization of the extr action dissolver, later impacting extraction duplicability. In order to get the better of the above disadvantage, low volatile ionic liquids were used in microwave assisted HS-SDME to roll up chlorobenzenes from aqueous samples prior to HPLC analysis ( ) . However, due to the declining public presentation of the column, both HPLC and GC are considered inappropriate methods to analyse the species in ionic liquids. In other manus, Yamini and Shamsipur introduced two H2O baths [ 8,9 ] to command the temperature of extractant and sample, severally. This optimized process was successfully applied to pull out and find analytes in H2O samples. But the low temperature of extractant was non truly realized because the ice bath was used to command the temperature of dissolver in the column of microsyringe but non at the tip of microsyringe acerate leaf. Besides the readying of the little extraction device is boring, particular tools are needed, and the duplicability of the device possibly non so good. Second, the solvent microdrop is unstable and easy to fall down from the acerate leaf, particularly when utilizing H2O mixable dissolvers as extractant. In order to increase the bead volume permitted for extraction, different alterations of the needle tip has been proposed, all of them based on increasing the contact country with the bead [ 21-23 ] . Ye et Al. [ 20 ] , was designed a little bell-mouthed extraction device with a 5mm Si gum elastic tubing or Teflon ( PTFE ) tubing, in which 20 _L 1-octantol was used as extractant without their dislodgment from the acerate leaf to preconcentrate weedkillers in H2O samples which showed improved extraction efficiency with high sensitiveness for HPLC analysis. Followed by, Xu et Al. was introduced a conic polypropene PCR tubing alternatively of the needle tip of a microsyringe in which more sum extractant could be suspended in the PCR tubing than microsyringe due to the larger interfacial tenseness. This method was successfully applied to find volatile CPs in existent aqueous samples. However, the extraction efficiency was improved through commanding the temperature of extractant merely by puting an ice bag around the PCR tubing. Besides this attack significantly complicates the experimental apparatus, particular tools are needed, and the duplicability of the device possibly non so good. Furthermore, extraction clip is longer and it should be used merely for extremely volatile analytes with low solvent-headspace distribution invariables due to the elevated temperatures tend to diminish the organic solvent-headspace distribution invariable, ensuing in lower sensitiveness of the finding. The loss of sensitiveness can be avoided if the pull outing dissolver is cooled while the sample is heated. In our old research plants, we demonstrated a fresh LPME method termed one-step microwave assisted controlled-temperature headspace liquid stage microextraction technique utilizing micro-liter sum of organic dissolver and which has been successfully applied for the analysis of chlorophenols and hexachlorocyclohexanes in environmental H2O samples utilizing GC-ECD ( ) . This new method utilizes an external-cooling system which controls the temperature of the heavy cloud of analyte-water vapour formed in the headspace LPME trying zone. It besides prevents the vaporisation of the LPME extraction dissolver. Meanwhile, it earned many virtues such as celerity, simpleness, easy to run, low cost, etc. and is a valuable and environmental friendly method. However, some disadvantages of LPME utilizing hollow fibre membranes, such as ( 1 ) being of a membrane barrier between the beginning ( sample ) stage and receiving ( acceptor ) stage cut down extraction rate and increase extraction clip ; ( 2 ) in two stages LPME extra sum of dissolver is needed for elution of analytes from lms and pores of fibre. Besides this procedure is a clip devouring measure ; ( 3 ) creative activity of air bubbles on the surface of the hollow fibre reduces the conveyance rate and decreases the duplicability of the extraction ; ( 4 ) in existent samples such as piss, effluent, etc. surface assimilation of hydrophobic substances on the fiber surface may barricade the pores. However, to our cognition, there is no study refering with the combination of one-step microwave warming coupled with temperature controlled bell-shape HS-SDME utilizing organic-aqueous mixture extractant for the extraction of chlorophenols analysis utilizing the SDME method. In continuance of our research work, we report here for the first clip the development and pertinence of the unmoved microwave-assisted temperature-controlled headspace single-drop micro-extraction ( MA-TC-HS-SDME ) for the rapid and efficient preconcentration of chlorphenols in complicated environmental aqueous samples towards effectual HPLC-UV finding. The present method reduces the extraction clip and the bounds of sensing values obtained are equal for hint analysis of chlorophenols in environmental H2O samples. The consequence of assorted experimental conditions on the extraction of chlorophenols are investigated and discussed in item. 2. Materials and methods 2.1. Reagents and Solutions 2-Chlorophenol ( 2-CP ) , 2,4-Dichlorophenol ( DCP ) and 2,4,6-trichlorophenol ( TCP ) were purchased from Aldrich ( Milwaukee, WI, USA ) and 2,3,4,6-tetrachlorophenol ( 2,3,4,6-TeCP ) was obtained from Lancaster Synthesis ( Ward Hill, MA, USA ) . HPLC-grade methyl alcohol, propanone and acetonitrile were obtained from Merck Chemicals ( Darmstadt, Germany ) . Sodium chloride and Na hydrated oxide were obtained from Merck Chemicals. Hydrochloric acid ( 36.4 % ) was from J.T. Baker ( Phillipsburg, USA ) .All chemicals used in the survey were of ACS reagent class. Ultrapure H2O for all aqueous solutions was produced in the research lab utilizing the Barnstead Nanopure H2O system ( Barnstead, New York, USA ) . Stock solutions ( 1 mg/mL of each analyte ) were prepared by fade outing chlorophenols in methonal and stored in brown glass bottles with PTFE-lined cap and kept 4 -C. Working solutions were obtained daily by suitably thining the stock solutions with H2O. Groundwater samples were collected from a deep well in west suburb of Beijing, river H2O samples from the Haihe River in Tianjin, China, effluent at a sewerage outfall of a effluent intervention mill in Beijing and tap H2O samples from our research lab after fluxing for about 5 min. These samples were all stored at the temperature of 4-C. 2.2. Instrumentality The extraction and injection were carried out utilizing a 25 _L HPLC microsyringe ( Shanghai, China ) . A S23-2 digital magnetic scaremonger ( Shanghai Sile Instrument Co. , China ) and a 5mm stirring saloon were used to stir the solution. HPLC analysis was carried out on a LC-10AT liquid chromatography ( Shimadzu, Japan ) with two LC-10ATvp pumps and a SPD-10Avp UV/vis sensor. Chromatographic separations were performed on a VP-ODS C18 column ( 250mm-4.6mm ID, atom size 5 _m ) ( Shimadzu, Japan ) . Data acquisition and procedure were accomplished with a Chromato-solution Light Workstation ( Shimadzu, Japan ) . The nomadic stage was H2O, methyl alcohol and acetonitrile ( 45:33:22, v/v/v ) at the flow rate of 0.6mLmin?1. Detection was set at 223 nanometer. Under these chromatographic conditions, baseline separation can be obtained for the mark compounds. 2.2. Instrumentality Analysis was carried out utilizing HP 5890 ( Hewlett Packard, Pennsylvania, USA ) gas chromatograph equipped with a split/split-less injector and an negatron gaining control sensor ( ECD, 63Ni ) . Compounds were separated on a amalgamate silicon oxide HP-5MS capillary column ( 30m x 0.25mm IDs, 0.25 Ã µm movie thickness ) ( Agilent Technologies, Palo Alto, CA, USA ) . Nitrogen was used as bearer gas and make-up gas at flow rates of 1.0 and 55 mL/min, severally. Gas chromatograph was operated in splitless manner with the injector temperature of 250 oC. The oven temperature was maintained at 100 oC for 2 min, and so programmed at 25 oC /min to 250 oC held for 4 min, and eventually 15 oC /min to 280 oC which was held for 4 min. The detached species were measured by negatron gaining control sensor held at 320 oC. A Peak-ABC Chromatography Data Handling System ( Kingtech Scientific, Taiwan ) was used to obtain chromatograms and to execute informations computations. 2.3. Microwave assisted controlled-temperature HS-LPME apparatus In this work, a modified domestic microwave oven ( NE-V27 inverter system, 2450 MHz, Panasonic system ) was used as the microwave energy beginning with a maximal power of 1400 W, which had a hole ( 2 centimeter diameter ) in the centre of the top surface of the microwave oven. A specially designed glass capacitor ( 25 centimeter length and fitted with an interior glass tubing of 1 centimeters diameter ) was placed steadfastly on the hole for the HS-LPME sampling and a go arounding water-hood system embracing a home-made magnetron driven stirrer device ( stirring velocity 500 revolutions per minute ) was placed inside the microwave oven. The glass capacitor and the go arounding water-hood system were connected to an external refrigerated electric bath ice chest machine ( Yih Der BL-720, Taiwan ) in order to command the temperature of headspace LPME trying zone chamber and to cut down the effectual power of microwave irradiation. The apparatus of the unmoved MA-CT-HS-LPME sampling syst em is shown in Figure 1. After the alteration, the effectual powers of microwave irradiation of 126, 170, 210, 249 and 279 W were used in this survey. To avoid escape of microwave irradiation, aluminium foils were wrapped on the inner and outer-walls of the microwave oven at the interface between the microwave organic structure and the headspace trying setup. A microwave leak sensor ( MD-2000, Less EMF, NY, USA ) was used to look into safety facets of the equipment during the experiments. Prior to the experiment, all the glasswork were exhaustively washed with soap solution, de-ionized H2O, propanone, and once more de-ionized H2O and so dried in the oven at 80 oC for 4 hour. A brace of flasks and capacitors was used alternately, because the interior surfaces of flasks and capacitors had to be exhaustively cleaned by propanone and de-ionized H2O between tallies to forestall carryover job from the glasswork apparatus. 2.4. MA-CT-HS-LPME Procedure The polypropene hollow fibre was cut into sections of 1.5-cm length and was washed ultrasonically with propanone for 1 hour. It was so dried and later kept in an organic dissolver ( 1-octanol ) for the impregnation of pores of the hollow fibre. After impregnation, the fibre was removed from 1-octanol and the syringe was aspirated so that the air in the syringe could blush the hollow fibre to take extra organic dissolver from inside the fibre. To construct an LPME investigation, approximately 4.0 milliliters of 1-octanol was taken in a conventional 10 milliliter microsyringe ( SGE Australia, Ringwood, Australia ) , and injected into the hollow fibre section mounted on the needle tip of the microsyringe. After an extraction, the extracted dissolver in hollow fibre was retracted to the barrel of the microsyringe, pushed and retracted for five rhythms. One microliter of the extracted dissolver was taken for GC-ECD analysis. The used hollow fibre was discarded and a new hollow fibre was u sed for each extraction. 10 milliliter of the sample solution was added into a 20-mL cylindrical shaped glass flask and fitted with glass capacitor for the external chilling of the trying zone, along with an LPME device in the headspace as shown in Figure 1. 3. Consequences and treatment There are assorted parametric quantities impacting the unmoved MA-CT-HS-LPME public presentation and efficiency for the finding of DDT and its chief metabolites by GC-ECD, including choice of LPME dissolver, trying place of LPME in the controlled-temperature headspace zone, microwave irradiation power and clip, sample pH and salting-out consequence. These parametric quantities were consistently investigated and the optimum conditions were so established.
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment
Note: Only a member of this blog may post a comment.